Repair Advice for Common Daikin Boiler Problems


Daikin boilers are a top choice for homeowners and professionals alike due to their reputation for quality and dependability. However like any appliance they can sometimes encounter issues. In this article we'll cover some common problems that Daikin boilers may experience and offer guidance on how to troubleshoot and repair them. Whether you're a homeowner trying to fix a problem yourself or a technician working on a repair job this information can help you get your Daikin boiler back up and running smoothly.

Free Repair Quotes? Apply online now!

No Heating/Hot Water

If your Daikin boiler is not producing heat or hot water there could be a few different issues at play. Here are some possible causes and solutions:

Thermostat problems

First, check that the thermostat is set to the correct temperature and that the batteries are working. If the thermostat seems fine try resetting it by turning it off and then on again. If the issue persists it may be a problem with the thermostat itself and it may need to be replaced.

Pilot light problems

If the pilot light is not lit it could be the cause of your heat and hot water issues. Try relighting the pilot light following the manufacturer's instructions. If the pilot light will not stay lit there may be a problem with the gas supply or the pilot light assembly and it will need to be checked by a professional.

Circulation issues

If the heat is not reaching your radiators or the hot water is not flowing it could be a circulation problem. Check the pumps and valves to make sure they are open and functioning properly. If they seem to be in working order there may be an issue with the water pressure or a blockage in the pipes that will need to be addressed by a professional.

Fan Speed Errors

One common problem that Daikin boilers may encounter is a fan speed error which can be caused by a variety of factors including a faulty fan motor or a problem with the control board. If your boiler is experiencing an error you may notice the following symptoms:

  • The boiler is not heating properly.
  • The boiler is making strange noises.
  • The boiler is cycling on and off frequently.

To troubleshoot a fan speed error you'll need to do the following:

  1. Check the fan blades for any damage or obstruction, if the blades are damaged or obstructed they may not be spinning at the correct speed which can cause a fan speed error.
  2. Inspect the fan motor for any visible damage, if the motor appears to be damaged it may need to be replaced.
  3. Check the control board for any errors or problems as the control board is responsible for controlling the fan speed so if it is not functioning properly it could cause an error to occur.

Low Boiler Pressure

If you have a Daikin boiler and you're experiencing low pressure there are a few possible causes and solutions to consider:

  • Check the pressure gauge: The pressure gauge should read between 1 and 1.5 bars when the boiler is cold. If it's significantly lower you may need to refill the system. To do this locate the filling loop and follow the manufacturer's instructions to refill the system to the correct pressure. Make sure to turn off the power supply and follow all safety precautions when working with the filling loop.
  • Check for leaks: Low pressure can be caused by leaks in the system. Check for visible signs of leakage such as puddles or dripping pipes and tighten any loose fittings. If you suspect a leak but can't find it try using a leak detection solution or contacting a professional for assistance.
  • Check the pressure relief valve: The pressure relief valve is a safety feature that releases excess pressure from the system. If it's faulty or stuck it can cause low pressure. Test the pressure relief valve by slowly turning the lever and observing whether it releases any water. If it doesn't you may need to replace the valve or contact a professional for assistance.

Radiators Not Working

If your radiators are not heating up there could be several possible causes. Here are a few things to check:

  • Make sure that the thermostat is set to a high enough temperature and that the boiler is turned on.
  • Check the pressure gauge on the boiler as if the pressure is too low it could be causing the radiators to not heat up. Try bleeding the radiators to remove any air pockets and bring the pressure back to the correct level.
  • Ensure that the valves on the radiators are open as these valves control the flow of hot water to the radiators and may have been closed accidentally.
  • If none of these solutions fix the problem it could be an issue with the pump or the boiler itself. In this case it's best to call a professional technician for further assistance.

Loss of Flame

One common issue that Daikin boilers may face is flame loss during operation which can be a serious problem as it can cause the boiler to shut down and potentially cause damage to the unit. If you notice an error code and that the flame on your Daikin boiler is going out during operation there are a few potential causes and solutions to consider:

  • Dirty burner: A dirty burner can cause the flame to go out so cleaning the burner and ensuring that it is free of debris can often fix this problem.
  • Faulty ignition system: If the ignition system is not functioning properly it can cause the flame to go out so check the ignition system and replace any damaged parts as needed.
  • Ventilation issues: If the boiler is not getting enough ventilation it can cause the flame to go out so be sure that the ventilation channels are clear and unobstructed.

Freeze Protection

One common problem that can occur with Daikin boilers is with the freeze protection system. If the temperature of the water in the boiler drops below zero it can cause the pipes to burst and result in serious damage so to prevent this from happening most Daikin boilers are equipped with freeze protection which shuts off the boiler and turns on a warning light if the water temperature drops too low.

If you're experiencing freeze protection issues with your Daikin boiler there are a few things you can try. First check the thermostat to make sure it is set to a temperature above freezing, then you should also check the water supply to the boiler and ensure that it is turned on and flowing properly.

If these steps don't resolve the issue it may be a problem with the freeze protection system itself and you may need to call a professional for repair.

Need a Repair? Apply online now!